Title of article
Pressure drop measurements in a low pressure steam condenser with a horizontal bundle of staggered tubes
Author/Authors
Bodius Salam، نويسنده , , David A. McNeil، نويسنده , , Bryce M. Burnside، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2004
Pages
15
From page
1365
To page
1379
Abstract
Pressure drop measurements were carried out in a test condenser of staggered configuration with p/D=1.33. The test conditions were: steam inlet pressure, 50 mbar, inlet velocity 10–30 m s−1 and steam-to-cooling water temperature difference 5–15 K. This corresponded to a mean bundle Rev,max between 1000 and 7000, suction parameter range 0.3–2.8 and heat flux densities at the tube outside wall up to 79 kW m−2. In the range 2800
Keywords
Steam condenser , Pressure drop , Effect of suction
Journal title
Applied Thermal Engineering
Serial Year
2004
Journal title
Applied Thermal Engineering
Record number
1025883
Link To Document