Title of article :
Heat transfer characteristics of a two-phase closed thermosyphon
Author/Authors :
S.H. Noie-Baghban، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2005
Abstract :
The applications of closed two-phase thermosyphons are increasing in heat recovery systems in many industrial practices because of their high effectiveness. Various parameters affect the heat transfer performance of thermosyphons. In this paper, the effect of three parameters: input heat transfer rates ( ), the working fluid filling ratios (30% ⩽ FR ⩽ 90%), and the evaporator lengths (aspect ratios) were investigated experimentally. The aspect ratios for these experiments were 7.45, 9.8, and 11.8. A series of experiments were carried out to find the influence of the above parameters on steady-state heat transfer characteristics of a vertical two-phase closed thermosyphon. A smooth copper tube of total length of 980 mm with inside and outside diameters of 25 and 32 mm was employed with distilled water as working fluid. The temperature distribution along the thermosyphon was monitored; input heat to evaporator section and output heat from condenser were measured, as well. The experimental boiling heat transfer coefficients were compared with existing correlations. Conclusions have been drawn for the optimum-filling ratio at which the thermosyphon operates at its best for a certain aspect ratio.
Keywords :
Heat pipes , Aspect ratio , Themosyphon , Boiling heat transfer , Thermal characteristics , Filling ratio
Journal title :
Applied Thermal Engineering
Journal title :
Applied Thermal Engineering