• Title of article

    Analytical effective length study of a flat plate heat pipe using point source approach

  • Author/Authors

    B.K. Tan، نويسنده , , T.N. Wong، نويسنده , , Steen K.T. Ooi، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2005
  • Pages
    13
  • From page
    2272
  • To page
    2284
  • Abstract
    An analytical approach is presented to evaluate the effective heat transport length of a flat plate heat pipe with multiple heat sources. In this study, point sources are modeled as the heat input to the heat pipe. The analysis is carried out by a proportioning concept of the heat pipe with reference to the heat source’s position and evaluates the respective heat transport paths. Minimum effective length is obtainable at the optimum heat source positions where the heat pipe pipe’s capillary heat transport limit is the highest and its operational performance is the best. Hence, it is useful in thermal management of electronic systems as this approach helps to determine the optimum heat source positions on the heat pipe that allows the cooling of electronic components or system more effectively and efficiently.
  • Keywords
    Point source , Flat plate heat pipe , Thermal management , Effective length
  • Journal title
    Applied Thermal Engineering
  • Serial Year
    2005
  • Journal title
    Applied Thermal Engineering
  • Record number

    1026176