• Title of article

    Bubble Dynamics Measurements Using Four-Point Optical Probe

  • Author/Authors

    Al-Dahhan، Muthanna H. نويسنده , , Xue، Junli نويسنده , , Dudukovic، M. P. نويسنده , , Mudde، R. F. نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2003
  • Pages
    -374
  • From page
    375
  • To page
    0
  • Abstract
    By conducting an analysis of the measurement errors it was found that bubble dynamics obtained by twopoint probes can be highly inaccurate. A four-point optical probe with appropriate data processing algorithm has been developed so that the bubble velocity vector can be obtained. This probe provides directly the value of specific gas-liquid interfacial area. However, for obtaining accurate values of bubble velocity and size, the four-point probe must be calibrated by a CCD camera at the same conditions. Calibration columns have been developed for this purpose where the bubble size and velocity can be varied to calibrate the measurements by the four-point optical probe against a CCD camera.
  • Journal title
    The Canadian Journal of Chemical Engineering
  • Serial Year
    2003
  • Journal title
    The Canadian Journal of Chemical Engineering
  • Record number

    102629