• Title of article

    Study of electrogenerated chemiluminescence of N-(β-carboxyl-propionyl)luminol Original Research Article

  • Author/Authors

    Guo Nan Chen، نويسنده , , Rong Er Lin، نويسنده , , Hui Sheng Zhuang، نويسنده , , Zheng Fan Zhao، نويسنده , , Xue Qi Xu، نويسنده , , Fan Zhang، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 1998
  • Pages
    7
  • From page
    269
  • To page
    275
  • Abstract
    It has been found that N-(β-carboxylpropionyl)luminol (CPL) gives electrogenerated chemiluminescence (ECL) at a platinum electrode in KCl–NaHCO3–Na2CO3 solution when a triangular pulse voltage is applied, and the presence of 5.8×10−4 mol l−1 H2O2 enhances this ECL. The optimum chemical conditions and electrochemical parameters for this ECL system have been investigated in detail. Under the optimum conditions the linear response range of CPL is 1.0×10−11–3.6×10−7 mol l−1, the detection limit was 1.0×10−11 mol l−1, and the relative standard deviation for 5×10−9 mol l−1 CPL was 5.8%. The mechanism for this ECL system is discussed.
  • Keywords
    N-(?-carboxyl–propionyl)luminol , Electrogenerated chemiluminescence
  • Journal title
    Analytica Chimica Acta
  • Serial Year
    1998
  • Journal title
    Analytica Chimica Acta
  • Record number

    1027200