Title of article :
Multiple reaction monitoring-based determination of bovine α-lactalbumin in infant formulas and whey protein concentrates by ultra-high performance liquid chromatography–tandem mass spectrometry using tryptic signature peptides and synthetic peptide stand
Author/Authors :
Jingshun Zhang، نويسنده , , Shiyun Lai، نويسنده , , Yu Zhang، نويسنده , , Baifen Huang، نويسنده , , Duo Li، نويسنده , , Yiping Ren، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2012
Pages :
7
From page :
47
To page :
53
Abstract :
The determination of α-lactalbumin in various dairy products attracts wide attention in multidiscipline fields because of its nutritional and biological functions. In the present study, we quantified the bovine α-lactalbumin in various infant formulas and whey protein concentrates using ultra-high performance liquid chromatography coupled to tandem mass spectrometer in multiple reaction monitoring mode. Bovine α-lactalbumin was quantified by employing the synthetic internal standard based on the molar equivalent relationship among the internal standard, bovine α-lactalbumin and their signature peptides. This study especially focused on the recovery rates of the sample preparation procedure and robust quantification of total bovine α-lactalbumin in its native and thermally denatured form with a synthetic internal standard KILDKVGINNYWLAHKALCSE. The observed recovery rates of bovine α-lactalbumin ranged from 95.8 to 100.6% and the reproducibility was excellent (RSD < 6%) at different spiking levels. The limit of quantitation is 10 mg/100 g for infant formulas and whey protein concentrates. In order to validate the applicability of the method, 21 brands of infant formulas were analyzed. The acquired contents of bovine α-lactalbumin were 0.67–1.84 g/100 g in these infant formulas in agreement with their label claimed values. The experiment of heat treatment time showed that the loss of native α-lactalbumin enhanced with an increasing intensity of heat treatment. Comparing with Renʹs previous method by analysis of only native bovine α-lactalbumin, the present method at the peptide level proved to be highly suitable for measuring bovine α-lactalbumin in infant formulas and whey protein concentrates, avoiding forgoing the thermally induced denatured α-lactalbumin caused by the technological processing.
Keywords :
?-Lactalbumin , Signature peptide , Tryptic peptide , Ultra-high performance liquid chromatography–tandem mass spectrometry , Infant formula
Journal title :
Analytica Chimica Acta
Serial Year :
2012
Journal title :
Analytica Chimica Acta
Record number :
1028412
Link To Document :
بازگشت