Title of article
Electrochemical determination of arsenic(III) on mercaptoethylamine modified Au electrode in neutral media Original Research Article
Author/Authors
Dongyue Li، نويسنده , , Jing Li، نويسنده , , Xiaofang Jia، نويسنده , , Yanchao Han، نويسنده , , Erkang Wang، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2012
Pages
5
From page
23
To page
27
Abstract
A simple, rapid and sensitive sensing platform for the detection of As(III) has been fabricated in neutral media based on the mercaptoethylamine modified Au electrode. A wide detection range of 0.2–300 μg L−1 and a low detection limit of 0.02 μg L−1 were obtained with a preconcentration time of 100 s under optimal conditions. Compared with previous studies, this work shows obvious advantages that it not only suppresses the Cu(II) interference, but also can detect the As(III) in natural water samples at the original pH avoiding high concentration acidic media. Moreover, the practical application of the proposed method was verified in the lake water sample determination.
Keywords
Neutral media , Arsenic(III) , Anodic stripping voltammetry , Copper(II) interference
Journal title
Analytica Chimica Acta
Serial Year
2012
Journal title
Analytica Chimica Acta
Record number
1028493
Link To Document