• Title of article

    A specific Tween-80-Rhodamine S-MWNTs phosphorescent reagent for the detection of trace calcitonin Original Research Article

  • Author/Authors

    Jia-Ming Liu، نويسنده , , Xiaomei Huang، نويسنده , , Lihong Zhang، نويسنده , , Zhiyong Zheng، نويسنده , , Bing-Xuan Lin، نويسنده , , Xiao-Yang Zhang، نويسنده , , Hong-li Jiao، نويسنده , , Ma-Lin Cui، نويسنده , , Shu-Lian Jiang، نويسنده , , Shao-Qin Lin، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2012
  • Pages
    8
  • From page
    60
  • To page
    67
  • Abstract
    The present study proposed a simple sensitive and specific immunoassay for the quantification of calcitonin (CT) in human serum with water-soluble multi-walled carbon nanotubes (MWNTs). The single bondCOOH group of MWNTs could react with the single bondNHsingle bond group of rhodamine S (Rhod.S) molecules to form Rhod.S-MWNTs, which could emit room temperature phosphorescence (RTP) on acetate cellulose membrane (ACM) and react with Tween-80 to form micellar compound. Tween-80-Rhod.S-MWNTs (TRM), as a phosphorescent labelling reagent, could dramatically enhance the RTP signal of the system. The developed TRM phosphorescent reagent was used to label anti-calcitonin antibody (AbCT) to form the TRM-AbCT labelling product, which could take high specific immunoreaction with CT, and the ΔIp (= Ip2 − Ip1, Ip2 and Ip1 were the phosphorescence intensity of the test solution and the blank sample, respectively) of the system was linear to the content of CT. Hence, a new solid substrate room temperature phosphorescence immunoassay (SSRTPIA) was established for the determination of CT in human serum. This sensitive (limit of quantification (LOQ) was 8.0 × 10−14 g mL−1), accurate, selective and precise method has been applied to determine CT in human serum and predict primary osteoporosis and fractures, with the results in good agreement with those obtained by chemiluminescence immunoassay (CLIA). Simultaneously, the structure of MWNTs was characterized with scanning electron microscopy (SEM) and infrared spectroscopy (IR), and the reaction mechanisms of both labelling AbCT with TRM and SSRTPIA for the determination of trace CT were discussed.
  • Keywords
    Prediction of human diseases , Tween-80-Rhodamine S-multi-walled carbon nanotubes phosphorescent reagent , Calcitonin , Solid substrate room temperature phosphorescence immunoassay
  • Journal title
    Analytica Chimica Acta
  • Serial Year
    2012
  • Journal title
    Analytica Chimica Acta
  • Record number

    1028643