Title of article :
Measurements of trace concentrations of mercury in sea water by stripping chronopotentiometry with gold disk electrode: influence of copper Original Research Article
Author/Authors :
Ricardo D. Riso، نويسنده , , Matthieu Waeles، نويسنده , , Philippe Monbet، نويسنده , , Christian J. Chaumery، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2000
Pages :
9
From page :
97
To page :
105
Abstract :
A stripping chronopotentiometric method, using a rotating gold disk electrode for mercury measurements in sea water is described. Compared with a same method using a stationary gold film electrode, this method has a eight times higher sensitivity and a detection limit of 5 ng l−1 after 10 min deposition time. Moreover, the time needed for gold plating is eliminated. Compared with other electrochemical methods capable of measuring mercury at low concentrations, the present method is more simplified with no degassing step and no need to use a medium-exchange procedure before the stripping step. These characteristics render the method easily practicable on board oceanographic vessels for ‘in situ’ measurements.
Keywords :
Stripping chronopotentiometry , Mercury analysis , Gold disk electrode , Sea water
Journal title :
Analytica Chimica Acta
Serial Year :
2000
Journal title :
Analytica Chimica Acta
Record number :
1028987
Link To Document :
بازگشت