Title of article :
Direct measurement of nitric oxide release from the rat hippocampus Original Research Article
Author/Authors :
Yuezhong Xian، نويسنده , , Wen Zhang، نويسنده , , Jian Xue، نويسنده , , Xiangyang Ying، نويسنده , , Litong Jin، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2000
Pages :
7
From page :
127
To page :
133
Abstract :
A novel, sensitive, selective and reproducible nitric oxide (NO) microsensor is developed for direct measurement of NO in vitro and in vivo. Using the microsensor, the first direct measurements NO release from the rat hippocampus are made. NO levels are increased by stimulated with l-arginine and acetylcholine. l–Nω-nitro-arginine, a NO synthase inhibitor, decreases the NO increase induced by l-arginine and acetylcholine. The effect of sodium nitroprusside, a NO donor, is also performed.
Keywords :
nitric oxide , Microsensor , Hippocampus