Title of article :
Internal validation of screening methodology for residues of epi-trenbolone, trenbolone, epi-nortestosterone and nortestosterone in bovine urine using immunoaffinity cartridges for sample clean-up Original Research Article
Author/Authors :
Leslie C Dickson، نويسنده , , James D. MacNeil، نويسنده , , JoAnn Reid، نويسنده , , Constance D Neiser، نويسنده , , Adrian C.E Fesser، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2002
Abstract :
This multi-analyte procedure uses commercially available immunoaffinity chromatography (IAC) clean-up cartridges for extraction and clean-up, followed by determination of residues of epi-trenbolone (ETB), trenbolone (TB), epi-nortestosterone (epi-nandrolone) (ENT) and nortestosterone (nandrolone) (NT) in bovine urine by liquid-chromatography with UV absorbance detection. This single-laboratory internal validation included assessment of recoveries, repeatability, linearity, detection capability and cross-reactivity (specificity) with a suite of antibiotics and other hormonal growth promotants (HGPs). The method was validated for screening at a target level of 2.0 ng ml−1.
Keywords :
Bovine urine , Hormones , validation , Screening , Immunoaffinity
Journal title :
Analytica Chimica Acta
Journal title :
Analytica Chimica Acta