• Title of article

    Direct determination of d-panthenol and salt of pantothenic acid in cosmetic and pharmaceutical preparations by differential pulse voltammetry Original Research Article

  • Author/Authors

    Lai-Hao Wang، نويسنده , , Shih-Wen Tseng، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2001
  • Pages
    10
  • From page
    39
  • To page
    48
  • Abstract
    d-Panthenol (provitamin B5) and salt of pantothenic acid are used in many cosmetic and pharmaceutical preparations for their skin emollient, regenerating and hair conditioning properties. The cathodic reduction of d-panthenol and salt of pantothenic acid had been studied by differential pulse voltammetry (DPV) at carbon paste electrode (CPE) and metal oxides modified CPE in the presence of cationic surfactants (stearyltrimethylammonium chloride, cetyltrimethylammonium chloride, dodecyltrimethylammonium chloride), anionic surfactants (sodium dodecyl sulfate, sodium dodecyl ether sulfate, sodium dodecylbenzenesulfonate) and non-ionic surfactants (TritonX-100, Span 60 and Tween 60) micelles. The peak potentials and peak currents have been found to be dependent on the character and concentration of the surfactant. The reduction potential of d-panthenol at a cobalt oxide modified CPE is shifted by 220 mV to more positive potential in the presence of the stearyltrimethylammonium chloride micelle. d-Panthenol and salt of pantothenic acid in commercial cosmetic and pharmaceutical preparations were determined by DPV using a cobalt oxide modified CPE in phosphate buffer (pH 6.08) solution. Comparison with results obtained from the spectrophotometry (SPM) shows good agreement.
  • Keywords
    Carbon paste electrode , Pantothenic acid , Spectrophotometry
  • Journal title
    Analytica Chimica Acta
  • Serial Year
    2001
  • Journal title
    Analytica Chimica Acta
  • Record number

    1032262