• Title of article

    Ultrasensitive fluorescent probe for the hydrophobic range of solvent polarities Original Research Article

  • Author/Authors

    Sebnem Ercelen، نويسنده , , Andrey S Klymchenko، نويسنده , , Alexander P Demchenko، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2002
  • Pages
    15
  • From page
    273
  • To page
    287
  • Abstract
    The new 3-hydroxychromone derivative 2-(6-diethylaminobenzo[b]furan-2-yl)-3-hydroxychromone (FA) displays a dramatic solvent-dependent transformation of fluorescence spectra in the range of low-polarity solvents. The two well-separated emission bands change their relative intensities so that the short-wavelength band being of a very low intensity in hexane becomes dominant in the more polar ethyl acetate and trichloromethane. We suggest the participation in this effect of excited-state intramolecular proton transfer, which is characteristic for other 3-hydroxychromone and 3-hydroxyflavone derivatives, in the range of solvents of much higher polarities. Because of these unique properties, a number of spectroscopic parameters (positions of absorption and two fluorescence maxima, the ratio of their intensities and the fluorescence quantum yield) can be measured in this solvent range with multiparametric analysis of the data. In terms of solvent polarity, the shifts in both emission bands and their intensity ratio demonstrate a good correlation with empirical polarity scales ETN, Py and SPP, while the absorption spectra reveal some deviations for the tested oxygen-containing solvent molecules. A good cross-correlation is observed between fluorescence spectral shifts and the ratio of band intensities. The latter provides the means for a dramatic amplification of solvent response. Thus, a new approach for ultrasensitive scaling and probing the solvent polarity in the low-polararity range can be suggested. It involves very simple ratiometric measurements at two emission bands and can be posed for a variety of applications. We present examples of these applications for distinguishing of polarities between methylated benzene derivatives, for quantitative assay of polar impurities in low-polar solvents and for detection of the changes of solvent polarity as a function of temperature.
  • Keywords
    Low-polar solvents , Fluorescence probe , Multiparametric solvent polarity scaling , 3-Hydroxychromones , Dual emission , Excited-state intramolecular proton transfer
  • Journal title
    Analytica Chimica Acta
  • Serial Year
    2002
  • Journal title
    Analytica Chimica Acta
  • Record number

    1033145