Title of article
Flow-injection chemiluminescence detection for studying protein binding for drug with ultrafiltration sampling Original Research Article
Author/Authors
Baoxin Li ، نويسنده , , Zhujun Zhang، نويسنده , , Lixia Zhao، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2002
Pages
6
From page
65
To page
70
Abstract
The novel flow chemiluminescence (CL) system for determination of pipemidic acid was proposed, which was based on the sensitizing effect of pipemidic acid on the CL oxidation of sulfite by KMnO4 in acid media. Combined with the technique of ultrafiltration, the flow-injection CL system was applied to study in vitro the bovine serum album (BSA) binding of pipemidic acid. The estimated association constant (K) and the number of the binding site (n) on one molecule of BSA were 8.81×104 l/mol and 0.94, respectively. The method provided a fast and simple technique for the study of drug–protein interaction.
Keywords
Chemiluminescence , Ultrafiltration sampling , Drug–protein interaction , Flow injection
Journal title
Analytica Chimica Acta
Serial Year
2002
Journal title
Analytica Chimica Acta
Record number
1033194
Link To Document