Title of article
Miniaturized measurement system for ammonia in air Original Research Article
Author/Authors
B.H. Timmer، نويسنده , , K.M. van Delft، نويسنده , , R.P. Otjes، نويسنده , , W. Olthuis، نويسنده , , A. van den Berg، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2004
Pages
7
From page
137
To page
143
Abstract
The development of a miniaturized ammonia sensor made using microsystem technology is described. Gas is sampled in a sampler comprising two opposite channels separated by a gas permeable, water repellent polypropylene membrane. Subsequently, the acid sample solution is pumped into a selector where an alkaline solution is added to ionize all sampled ambient acid gasses, resulting in an enhanced selectivity. In the selector, the ammonia can diffuse through a second membrane into a purified water stream where an electrolyte conductivity sensor quantifies the resulting ammonium concentration. The realized system is shown to be selective enough not to be influenced by normal ambient carbon dioxide concentrations. Experiments with a gas flow of 3 ml/min, containing ammonia concentrations ranging from 9.8 to 0.3 ppm in a nitrogen carrier flow, into a 15 μl/min sample solution flow and finally into a 5 μl/min purified water stream have been carried out and show that the system is sensitive to ammonia concentration below 1 ppm.
Keywords
Gaseous ammonia sensor , Microfluidics
Journal title
Analytica Chimica Acta
Serial Year
2004
Journal title
Analytica Chimica Acta
Record number
1033899
Link To Document