• Title of article

    A new method and apparatus for on-site detection of trace levels of chemical warfare agents Original Research Article

  • Author/Authors

    Shai Kendler، نويسنده , , Adi Zifman، نويسنده , , Natzach Gratziany، نويسنده , , Amalia Zaltsman، نويسنده , , Gad Frishman، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2005
  • Pages
    8
  • From page
    58
  • To page
    65
  • Abstract
    A pre-concentration/fast gas chromatograph for the sampling of toxic vapors from air was developed. Pre-concentration is performed by filtering the contaminated air through a tube containing absorbing material. The sample is thermally desorbed and separated on a short chromatographic column using air as a carrier gas. Detection is performed with a commercial hand-held chemical warfare agent detector. The effects of the airflow rate, sample volume and system temperatures on the analytical performance were studied. Detection of organophosphorus vapors at concentrations in the range 4 × 10−4 to 4 × 10−5 mg/m3 was achieved within 2.5 min. The ability to couple a portable detector to a pre-concentration/fast GC using air as a carrier gas encourages the development of a hand-held device for real-time on-site monitoring of low levels of CWA in the air.
  • Keywords
    CWA , Pre-concentration , Fast-GC , On-site
  • Journal title
    Analytica Chimica Acta
  • Serial Year
    2005
  • Journal title
    Analytica Chimica Acta
  • Record number