• Title of article

    PARAFAC and PARAFAC2 calibration models for antihypertensor Nifedipine quantification Original Research Article

  • Author/Authors

    Jo?o M.M. Leit?o، نويسنده , , Joaquim C.G. Esteves da Silva، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2006
  • Pages
    10
  • From page
    271
  • To page
    280
  • Abstract
    Two-way data structures were obtained by acquiring UV–vis spectra as function of the time of the alkaline hydrolysis reaction of the antihypertensor Nifedipine in dimethylsulfoxide (DMSO). Sets of three-way data structures were obtained from the analysis of solutions with different concentrations of Nifedipine generated by standard additions to DMSO, Nifedipine standard and a pharmaceutical formulation. PARAFAC and PARAFAC2 methods were used in the analysis of these multi-way data structures and calibration models were developed for Nifedipine quantification in pharmaceutical formulations. For all the three-way data structures a better model fit was found with the PARAFAC2 suggesting that the experimental data sets have deviations from trilinearity. The best concentrations estimations were found with the PARAFAC2 model in the analysis of a [concentration × time (s) × wavelength (nm)] three-way data structure which allows the quantification of Nifedipine in pharmaceutical formulations.
  • Keywords
    Calibration models , UV–Vis spectroscopy , Antihypertensor Nifedipine , PARAFAC , PARAFAC2 , Alkaline hydrolysis
  • Journal title
    Analytica Chimica Acta
  • Serial Year
    2006
  • Journal title
    Analytica Chimica Acta
  • Record number