Title of article :
Adsorptive stripping voltammetric measurements of trace beryllium at the mercury film electrode Original Research Article
Author/Authors :
Joseph Wang، نويسنده , , Sompong Thongngamdee، نويسنده , , Donglai Lu، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2006
Pages :
5
From page :
248
To page :
252
Abstract :
A highly sensitive adsorptive stripping voltammetric protocol for measuring trace beryllium, in which the preconcentration is achieved by adsorption of the beryllium–arsenazo-I complex at a preplated mercury-coated carbon-fiber electrode, is described. Optimal conditions were found to be a 0.05 M ammonium buffer (pH 9.7) containing 5 μM arsenazo-I, an accumulation potential of 0.0 V (versus Ag/AgCl) and a square-wave voltammetric scan. The new procedure obviates the need for renewable mercury-drop electrodes used in early stripping protocols for beryllium. A linear response is observed over the 10–60 μg l−1 concentration range (90 s accumulation), along with a detection limit of 0.25 μg l−1 beryllium (10 min accumulation). A 15-s electrochemical cleaning enables the same mercury film to be used for a prolonged operation. High stability is thus indicated from the reproducible response of a 100 μg l−1 beryllium solution (n = 60; RSD = 3.3%) over a 2.5-h operation. Applicability to a seawater sample is illustrated. The attractive behavior of the new sensor holds great promise for on-site environmental and industrial monitoring of beryllium. Preliminary data in this direction using mercury-coated screen-printed electrodes are encouraging.
Keywords :
Beryllium , Mercury film electrode , Arsenazo-I , Adsorptive stripping voltammetry
Journal title :
Analytica Chimica Acta
Serial Year :
2006
Journal title :
Analytica Chimica Acta
Record number :
1035774
Link To Document :
بازگشت