• Title of article

    2-(2-Phenyl-1H-phenanthro-[9,10-d]imidazole-1-yl)-acetic acid (PPIA) and its application for determination of amines by high performance liquid chromatography with fluorescence detection and identification with mass spectroscopy/atmospheric pressure chemi

  • Author/Authors

    Jinmao You، نويسنده , , Xianen Zhao، نويسنده , , Yourui Suo، نويسنده , , Honglun Wang، نويسنده , , Yulin Li، نويسنده , , Jing Sun، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2006
  • Pages
    10
  • From page
    168
  • To page
    177
  • Abstract
    A simple, sensitive, and mild method for the determination of amino compounds based on a condensation reaction with 1-ethyl-3-(3-dimethylaminopropyl)-carbodiimide hydrochloride (EDC·HCl) as the dehydrant with fluorescence detection has been developed. Amines were derivatized to their acidamides with labeling reagent 2-(2-phenyl-1H-phenanthro-[9,10-d]imidazole-1-yl)-acetic acid (PPIA). Studies on derivatization conditions indicated that the coupling reaction proceeded rapidly and smoothly in the presence of a base catalyst in acetonitrile to give the corresponding sensitively fluorescent derivatives with an excitation maximum at λex 260 nm and an emission maximum at λem 380 nm. The labeled derivatives exhibited high stability and were enough to be efficiently analyzed by high-performance liquid chromatography. Identification of derivatives was carried out by online post-column mass spectrometry (LC/APCI–MS/MS) and showed an intense protonated molecular ion corresponding m/z [MH]+ under APCI in positive-ion mode. At the same time, the fluorescence properties of derivatives in various solvents or at different temperature were investigated. The method, in conjunction with a gradient elution, offered a baseline resolution of the common amine derivatives on a reversed-phase Eclipse XDB-C8 column. LC separation for the derivatized amines showed good reproducibility with acetonitrile–water as mobile phase. Detection limits calculated from 0.78 pmol injection, at a signal-to-noise ratio of 3, were 3.1–18.2 fmol. The mean intra- and inter-assay precision for all amine levels were <3.85% and 2.11%, respectively. Excellent linear responses were observed with coefficients of >0.9996. The established method for the determination of aliphatic amines from real wastewater and biological samples was satisfactory.
  • Keywords
    HPLC , Amines , 10-d]imidazole-1-yl)-acetic acid (PPIA) , mass spectrometry
  • Journal title
    Analytica Chimica Acta
  • Serial Year
    2006
  • Journal title
    Analytica Chimica Acta
  • Record number

    1035801