Title of article :
A disposable immunosensor for detection of 17β-estradiol in non-extracted bovine serum Original Research Article
Author/Authors :
Alessandra G. Volpe، نويسنده , , G. Fares، نويسنده , , F. Delli Quadri، نويسنده , , R. Draisci، نويسنده , , G. Ferretti، نويسنده , , C. Marchiafava، نويسنده , , D. Moscone، نويسنده , , G. Palleschi، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2006
Pages :
6
From page :
11
To page :
16
Abstract :
This paper reports the assembly of a disposable immunosensor based on the direct competitive enzyme-linked immunosorbent assay (ELISA), for simple and fast measurement of 17β-estradiol (17β-E2) in bovine serum, using screen-printed electrodes (SPEs) and a Palm-Sens portable electrochemical detector. The immunosensor strip was assembled immobilising, by passive adsorption, anti-rabbit IgG onto the surface of the working SPE electrode. After the interaction between anti-rabbit IgG and rabbit anti-17β-E2 polyclonal antibodies (PAb), the competition was performed using 17β-estradiol–alkaline phosphatase conjugate (17β-E2–AP) synthesised in our laboratory. The enzymatic substrate used for signal generation was 1-naphthylphosphate and its conversion to an electroactive product (1-naphthol) was measured using differential pulse voltammetry (DPV). To develop a prototype for field measurements, the entire competitive protocol has been optimised directly in a blank non-extracted bovine serum. According to the new EU criteria established by the Commission Decision 2002/657/EC for qualitative and quantitative screening methods, the detection capability (CCβ), was determined. The CCβ value resulted below the action limit (40 pg mL−1) fixed for 17β-E2. Spiked and real samples were analysed using the electrochemical immunostrips obtaining precision values (relative standard deviation, R.S.D.%) ranging from 8.6 to 17.0% and a recovery (R%) from 88.2 to 120.0%. Results obtained on real samples were confirmed by liquid chromatography coupled on-line with tandem mass spectrometry (LC-MS/MS) using an atmospheric pressure chemical ionisation (APCI) source and a heated nebulizer (HN) interface; this is the method currently used to confirm illegal hormone administration for regulatory purposes. The disposable immunosensor appears suitable as a screening tool for field analysis of bovine serum estradiol.
Keywords :
17?-estradiol , Electrochemical disposable immunosensor , Non-extracted bovine serum
Journal title :
Analytica Chimica Acta
Serial Year :
2006
Journal title :
Analytica Chimica Acta
Record number :
1035986
Link To Document :
بازگشت