• Title of article

    Microwave-assisted extraction through an aqueous medium and simultaneous cleanup by partition on hexane for determining pesticides in agricultural soils by gas chromatography: A critical study Original Research Article

  • Author/Authors

    Edwar Fuentes، نويسنده , , Mar?a E. B?ez، نويسنده , , Dana Reyes، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2006
  • Pages
    9
  • From page
    122
  • To page
    130
  • Abstract
    A simple microwave-assisted extraction and partitioning method (MAEP) using water–acetonitrile and n-hexane for desorption and simultaneous partitioning, respectively, together with gas chromatography (GC) was studied to determine representative pesticides (trifluralin, metolachlor, chlorpyriphos and triadimefon) with a broad range of physico-chemical properties in agricultural soils. Three points were considered crucial in this study: instrumental and sample-associated factors affecting extraction of the target compounds were studied through experimental design; the spiking procedure at trace levels was carried out to reproduce the solute-soil sorption taking place in the environment as closely as possible; and results were analyzed taking into account the adsorption behaviour of the compounds on different kinds of soils. The complete analytical procedure proposed consisted of the MAEP of pesticides from 1.0 g of soil with 1 mL of 1:1 water/acetonitrile mixture, and 5 mL of hexane for trapping. The microwave heating program applied was 2 min at 250 W and 10 min at 900 W, and 130 °C maximum temperature. After extraction, the hexane layer was evaporated to dryness; the residue was re-dissolved and directly analyzed by gas chromatography electron capture detection (GC-ECD). Clean chromatograms were obtained without any additional cleanup step. Besides the four pesticides used to optimise MAEP, the method was applied to determine an additional group of pesticides (triallate, acetochlor, alachlor, endosulphan I and II, endrin, methoxychlor and tetradifon) in different soils. Most of the compounds studied were recovered in good yields with relative standard deviations (R.S.D.s) below 9% and detection limits ranged from 0.004 to 0.036 μg g−1. The described method is efficient and fast to determine hydrophobic pesticides at ng g−1 level in soil with different clay-to-organic matter ratios.
  • Keywords
    Soils , Microwave-assisted extraction , Water–hexane partition , Pesticides
  • Journal title
    Analytica Chimica Acta
  • Serial Year
    2006
  • Journal title
    Analytica Chimica Acta
  • Record number

    1036306