Title of article
Determination of traces of rubidium in high purity cesium chloride by electrothermal atomic absorption spectrometry (ETAAS) using boric acid as a modifier Original Research Article
Author/Authors
K. Dash، نويسنده , , S. Thangavel، نويسنده , , S.C. Chaurasia، نويسنده , , J. Arunachalam، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2007
Pages
5
From page
210
To page
214
Abstract
The use of boric acid as a modifier for the determination of trace amount of rubidium in high purity cesium chloride matrix by electrothermal atomic absorption is described. It was found that the negative influence of the chloride matrix could not be eliminated using stabilized temperature platform (STPF) alone. Due to the high dissociation energy (D0 = 427 kJ mol−1) of rubidium chloride, it was difficult to dissociate in the gas phase and hence is lost. Elimination of interferences was achieved by the addition of boric acid as a chemical modifier. Diluted cesium chloride samples (5%, m/v) were analyzed applying the standard addition method. The characteristic mass of 24 pg was obtained. The detection limit of the proposed method is around 26 ng g−1. The developed method was applied to the determination of traces of rubidium in high purity cesium chloride samples. The data obtained by this method were in good agreement with those obtained by other independent method like FAAS.
Keywords
Rubidium , Boric acid modifier , Chloride interference , Cesium chloride