• Title of article

    A sensitive fluorescence reagent for the determination of aldehydes from alcoholic beverage using high-performance liquid chromatography with fluorescence detection and mass spectrometric identification Original Research Article

  • Author/Authors

    Jinmao You، نويسنده , , Tao Yan، نويسنده , , Huaixin Zhao، نويسنده , , Zhiwei Sun، نويسنده , , Lian Xia، نويسنده , , Yourui Suo، نويسنده , , Yulin Li، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2009
  • Pages
    10
  • From page
    95
  • To page
    104
  • Abstract
    A pre-column derivatization method for the sensitive determination of aldehydes using the tagging reagent 2-[2-(7H-dibenzo[a,g] carbazol-7-yl)-ethoxy] ethyl carbonylhydrazine (DBCEEC) followed by high-performance liquid chromatography with fluorescence detection and APCI-MS identification has been developed. The chromophore of fluoren-9-methoxy-carbonylhydrazine (Fmoc-hydrazine) reagent was replaced by 2-[2-(7H-dibenzo[a,g] carbazol-7-yl)-ethoxy] ethyl functional group, which resulted in a sensitive fluorescence tagging reagent DBCEEC. DBCEEC could easily and quickly labeled aldehydes. The maximum excitation (300 nm) and emission (400 nm) wavelengths did not essentially change for all the aldehyde derivatives. Derivatives were sufficiently stable to be efficiently analyzed by high-performance liquid chromatography. The derivatives showed an intense protonated molecular ion corresponding m/z [M + (CH2)n]+ in positive-ion mode (M: molecular weight of DBCEEC, n: corresponding aldehyde carbon atom numbers). The collision-induced dissociation of protonated molecular ion formed fragment ions at m/z 294.6, m/z 338.6 and m/z 356.5. Studies on derivatization demonstrated excellent derivative yields in the presence of trichloroacetic acid (TCA) catalyst. Maximal yields close to 100% were observed with a 10 to 15-fold molar reagent excess. Separation of the derivatized aldehydes had been optimized on ZORBAX Eclipse XDB-C8 column with aqueous acetonitrile as mobile phase in conjunction with a binary gradient elution. Excellent linear responses were observed at the concentration range of 0.01–10 nmol mL−1 with coefficients of >0.9991. Detection limits obtained by the analysis of a derivatized standard containing 0.01 nmol mL−1 of each aldehyde, were from 0.2 to 1.78 nmol L−1 (at a signal-to-noise ratio of 3).
  • Keywords
    Column liquid chromatography , Aldehydes , mass spectrometry , g] carbazol-7-yl)-ethoxy] ethyl carbonylhydrazine (DBCEEC)
  • Journal title
    Analytica Chimica Acta
  • Serial Year
    2009
  • Journal title
    Analytica Chimica Acta
  • Record number

    1037130