A new ordered mesoporous carbon (OMC) composite modified electrode was fabricated for the first time. Binuclear cobalt phthalocyaninehexasulfonate sodium salt (bi-CoPc) can be adsorbed onto didodecyldimethylammonium bromide (DDAB)/OMC film by ion exchange. UV–vis spectroscopy, scanning electron microscopy (SEM) and electrochemical methods were used to characterize the composite film. The cyclic voltammograms demonstrate that the charge transfer of bi-CoPc is promoted by the presence of OMC. Further study indicated that bi-CoPc/DDAB/OMC film is the excellent electrocatalyst for the electrochemical reduction of oxygen in a neutral aqueous solution and hemoglobin (Hb) at lower concentrations. Additionally, as an amperometric 2-mercaptoethanol (2-ME) sensor, this modified electrode shows a wider linear range (2.5 × 10−6 to 1.4 × 10−4 M), high sensitivity (16.5 μA mM−1) and low detection limit of 0.6 μM (S/N = 3). All these confirm the fact that the new composite film may have wide potential applications in biofuel cells, biological and environmental sensors.