• Title of article

    Performance analysis of a 0.3-Tb/in/sup 2/ low-power MFM-based scanning-probe device

  • Author/Authors

    L.R.، Carley, نويسنده , , R.T.، El-Sayed, نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2003
  • Pages
    -3565
  • From page
    3566
  • To page
    0
  • Abstract
    In this paper, we present an analysis of the performance of a 0.3Tb/in/sup 2/ ultralow-power magnetic-force-microscopy-based scanning-probe storage device actuated by microelectromechanical systems technology. The device is currently under development at Carnegie Mellon University, Pittsburgh, PA. The analysis shows that, with an optimized commercial single-layered Co-based perpendicular medium with an optimized tip trajectory, a signal-to-noise ratio of 2025 dB is achievable. The analysis includes general design considerations as well as various aspects of performance such as recording dynamics, PW/sub 50/, intersymbol-interference limit, detection sensitivity, thermal degradation, intertrack interference, off-track errors, process variations, and surface fluctuation effect. Design/performance standards for the new device are suggested.
  • Keywords
    Genotype , OBESITY , Energy
  • Journal title
    IEEE TRANSACTIONS ON MAGNETICS
  • Serial Year
    2003
  • Journal title
    IEEE TRANSACTIONS ON MAGNETICS
  • Record number

    104014