The influence of the operating pressure on the stability of natural circulation systems
Author/Authors
H. Walter، نويسنده , , W. Linzer، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2006
Pages
6
From page
892
To page
897
Abstract
Static flow instability, namely reverse flow, in a natural circulation system with two unequally heated riser systems, which are fed by the same unheated downcomer, were numerically investigated. The boiler was analysed under variable operating pressures. The dependence of the critical heat absorption ratio Vcrit from the pressure is discussed. A lower boundary for the part load operation of the analysed natural circulation steam generator was determined. Modifications of the boiler geometry were analysed and the calculation results were presented and discussed.
Keywords
Two-phase flow , Static flow instability , Reverse flow , Natural circulation system , Critical heat absorption ratio , Numerical analysis