• Title of article

    Design and evaluation of a nitrogen purge system for the front opening unified pod (FOUP)

  • Author/Authors

    Shih-Cheng Hu، نويسنده , , Tzong-Ming Wu، نويسنده , , Hong-Chong Lin، نويسنده , , Kwen Hsu، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2007
  • Pages
    8
  • From page
    1386
  • To page
    1393
  • Abstract
    The technology roadmap toward smaller structures and thinner layers in semiconductor manufacturing directs attention more and more toward yield-affecting influences from the air quality of manufacturing environment. The so-called airborne molecular contaminants (AMCs) have become a key issue related to production yield. A useful method for reducing AMC is purging of wafer with nitrogen gas. In this study, parametric studies on purging a front opening unified pod (FOUP), a wafer box for handling 300-mm wafers, are studied by theoretical analysis, CFD simulation and experimental measurement. The results show that the inlet purge gas through plenum injector with 60° of diverging exhibits faster decrease in oxygen concentration than that with greater degree cases. The depletion on the 1st wafer is slow because of the uni-distance configuration of holes of the plenum injector, which created a non-uniform purge gas inlet profile. By adopting a ceramic plenum injector, a uniform inlet purge gas profile is created and the purge efficiency is therefore significantly improved.
  • Keywords
    Contamination control , Airborne molecular contaminant (AMC) , FOUP , Purge system
  • Journal title
    Applied Thermal Engineering
  • Serial Year
    2007
  • Journal title
    Applied Thermal Engineering
  • Record number