• Title of article

    Experimental study on R-134a refrigeration system using a two-phase ejector as an expansion device

  • Author/Authors

    Praitoon Chaiwongsa، نويسنده , , Somchai Wongwises، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2008
  • Pages
    11
  • From page
    467
  • To page
    477
  • Abstract
    This paper is a continuation of the authors previous work. In the present paper, the performance of the refrigeration cycle using a two-phase ejector as an expansion device is experimentally investigated. Refrigerant R-134a is used as working fluid. Motive nozzles having three different outlet diameters are tested. New experimental data that have never been seen before are presented on the effects of the external parameters i.e. heat sink and heat source temperatures on the coefficient of performance and various relevant parameters i.e. primary mass flow rate of the refrigerant, secondary mass flow rate of the refrigerant, recirculation ratio, average evaporator pressure, compressor ratio, discharge temperature and cooling capacity. The effects of size of the motive nozzle outlet on the system performance are also discussed.
  • Keywords
    Two-phase ejector , Refrigeration , Liquid-recirculation , Coefficient of performance , Motive nozzle , Expansion device
  • Journal title
    Applied Thermal Engineering
  • Serial Year
    2008
  • Journal title
    Applied Thermal Engineering
  • Record number

    1041543