• Title of article

    Development of LHPs with ceramic wick

  • Author/Authors

    Paulo H.D. Santos، نويسنده , , Edson Bazzo، نويسنده , , Susanne Becker، نويسنده , , Rudi Kulenovic، نويسنده , , Rainer Mertz، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2010
  • Pages
    6
  • From page
    1784
  • To page
    1789
  • Abstract
    The ceramic porous wick is proposed as an alternative to wicks made of metal and plastic for Loop Heat Pipes (LHP) applications. Performance tests of two LHPs using acetone and water as working fluids were carried out for power inputs up to 25 W. The evaporators have a stainless steel cylindrical assembly, with 80 mm of length and 10 mm of inner diameter. The ceramic porous wick has 50% of porosity, 1–3 μm of pore radius distribution and a permeability of about 35 × 10−15 m2. The active zone length of the evaporators is 25 mm. For a limited operation temperature of 100 °C, the LHPs were able to transfer up to 25 and 15 W using acetone and water, respectively, at steady state condition. An operation analysis concerning the effects of the LHP inclination, the heat sink temperature and LHP thermal resistances is also presented. Despite the relative good performance of the LHPs, further researches are still required taking into account changes related to properties of the ceramic porous wick in particular and improvements in the whole LHP design in general.
  • Keywords
    Acetone , LHP , Water , Ceramic porous wick
  • Journal title
    Applied Thermal Engineering
  • Serial Year
    2010
  • Journal title
    Applied Thermal Engineering
  • Record number