Title of article :
Experimental study on household refrigerator with diffuser pipe
Author/Authors :
Yicai Liu، نويسنده , , Kai Chen، نويسنده , , Tianlong Xin، نويسنده , , Lihong Cao، نويسنده , , Siming Chen، نويسنده , , Lixin Chen ، نويسنده , , Weiwu Ma، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2011
Pages :
6
From page :
1468
To page :
1473
Abstract :
To reduce the energy consumption of household refrigerators, a better understanding of the flow passing through the ejectors (diffuser pipe) is needed. The refrigerator with diffuser pipe was constructed in this study and then compared with a refrigerator without an exhaust/suction-pressurized and energy-saving diffuser pipe. The energy consumption levels of the two refrigeration systems under various operating conditions were measured. Using the collected data, the flow characteristics through the diffuser pipe were clearly understood. Results showed that the energy consumption of the prototype refrigerator (Electrolux BCD-252T) was 0.575 kWh d−1, representing a reduction rate of 8.0%.
Keywords :
Energy saving , Refrigerator , Diffuser pipe , Experiment
Journal title :
Applied Thermal Engineering
Serial Year :
2011
Journal title :
Applied Thermal Engineering
Record number :
1045534
Link To Document :
بازگشت