Title of article :
Experimental study on frosting control of mobile air conditioning system with microchannel evaporator
Author/Authors :
Xiaohua Qu، نويسنده , , Junye Shi، نويسنده , , Zhaogang Qi، نويسنده , , Jiangping Chen، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2011
Pages :
9
From page :
2778
To page :
2786
Abstract :
In this paper, a newly developed frost control system is proposed. System bench tests and vehicle test in wind tunnel have been carried out to explore the anti-frosting performance of automotive air conditioning system with microchannel evaporator. The experimental results are compared with the baseline conventional laminated evaporator system. The test results show that the installation position of temperature sensor can dramatically affect the anti-frosting performance. The clutch switching on/off temperature range of the microchannel evaporator is also experimentally studied. The test results show that, with a proper installation position and on/off temperature range, the system COP can be improved, and meanwhile the panel vents’ air off temperature can be reduced, and temperature swing can be reduced.
Keywords :
Mobile air conditioning (MAC) system , Microchannel evaporator , Frosting , Experiment
Journal title :
Applied Thermal Engineering
Serial Year :
2011
Journal title :
Applied Thermal Engineering
Record number :
1045687
Link To Document :
بازگشت