Title of article :
A frequency-domain detection of stator winding faults in induction machines using an external flux sensor
Author/Authors :
G.-A.، Capolino, نويسنده , , H.، Henao, نويسنده , , C.، Demian, نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2003
Abstract :
The aim of this paper is to present the advantage of stator fault detection using an external stray flux sensor in a working induction machine. In the past 20 years, stray flux sensors have been used for diagnostic purposes but rarely in the presence of a complex power supply such as a voltage static inverter. In this paper, it is proved that a simple external stray flux sensor is more efficient than the classical stator current signature analysis to detect inter-turn short circuit in three-phase induction machines. The new result is that, even in the presence of power supply harmonics, it is possible to easily detect the stator winding faults in the low-frequency range of the flux spectrum with low-frequency resolution.
Keywords :
Distributed systems
Journal title :
IEEE Transactions on Industry Applications
Journal title :
IEEE Transactions on Industry Applications