Optimal common-mode Voltage reduction PWM technique for inverter control with consideration of the dead-time effects-part I: basic development
Author/Authors :
Lai، Yen-Shin نويسنده , , Shyu، Fu-San نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2004
Pages :
8
From page :
1605
To page :
1612
Abstract :
The objective of this paper is to investigate the optimal common-mode voltage reduction pulsewidth modulation (PWM) technique when dead-time effect is taken into account. The effect of dead time on common-mode voltage for inverter control and the associated solution are discussed. Based upon these results, an optimal common-mode voltage reduction PWM technique, which requires no extra voltage/current sensors and compensation mechanism while not being affected by the dead time, is recommended. The common-mode voltage can be reduced to one-third for the inverter with diode front end, which is widely used in industry. Intensive measured results are presented to fully support the claims.