Title of article :
Implications of shorted turn faults in bar wound PM machines
Author/Authors :
A.J.، Mitcham, نويسنده , , G.، Antonopoulos, نويسنده , , J.J.A.، Cullen, نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2004
Abstract :
The paper discusses the effect of single turn short-circuits in the windings of fault tolerant permanent magnet machines. It is shown that previously recognised methods for dealing with shorted turns do not work for larger bar-wound machines, and a new method for protecting the windings against single turn faults is therefore proposed. The new method depends on rapid detection of the fault and injection of a current (of appropriate magnitude and phase) into the faulted winding. The paper gives a theoretical analysis supported by finite element simulations of the fault conditions and illustrates these with a case study taken from the aerospace industry.
Journal title :
IEE Proceedings Electric Power Applications
Journal title :
IEE Proceedings Electric Power Applications