Title of article
Inhibition of CO2 corrosion of carbon steel with 1% Cr
Author/Authors
L.D. Paolinelli، نويسنده , , B. Brown، نويسنده , , S.N Simison، نويسنده , , S. Nesic، نويسنده ,
Issue Information
دوهفته نامه با شماره پیاپی سال 2012
Pages
11
From page
1092
To page
1102
Abstract
One of the most employed methods for CO2 corrosion control in oil and gas production and transportation industry is the use of carbon and low alloy steels in conjunction with corrosion inhibitors. The inhibitor performance can be influenced by the microstructure and chemical composition of the steel. In previous works, it was shown that 1% Cr addition to carbon steel decreased the protectiveness of a commercial imidazoline-based inhibitor. However, it was suspected that changing the flow rates may modify the inhibitor behaviour. In the present work, the performance of an imidazoline-based inhibitor was investigated on two carbon steels one with the other without 1% Cr, under different flow rates.
Keywords
Corrosion , Electrochemical techniques , Alloys , SEM