Title of article
Three-level inverter configuration cascading two two-level inverters
Author/Authors
K.، Gopakumar, نويسنده , , V.T.، Somasekhar, نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2003
Pages
10
From page
245
To page
254
Abstract
A power circuit configuration to realise three-level inversion is proposed. Three-level inversion is realised by connecting two two-level inverters in cascade, in the proposed configuration. An isolated DC power supply is used to supply each inverter in this power circuit. Each DC-link voltage is equal to half of the DC-link voltage in a conventional NPC (neutral point clamped) three-level inverter topology. Neutral point fluctuations are absent, and fast recovery neutral clamping diodes are not needed. The proposed inverter scheme produces 64 space-vector combinations distributed over 19 space-vector locations as compared to 27 combinations in a conventional three-level topology. The present power circuit can be operated as a two-level inverter in the range of lower modulation, by clamping one inverter to a zero state and by switching the other inverter. When compared to the H-bridge topology, this circuit needs one power supply less. A space vector based PWM scheme is used for the experimental verification of the proposed topology.
Keywords
Distributed systems
Journal title
IEE Proceedings Electric Power Applications
Serial Year
2003
Journal title
IEE Proceedings Electric Power Applications
Record number
106518
Link To Document