• Title of article

    Suspension-to-membrane-wall heat transfer in a circulating fluidized bed combustor

  • Author/Authors

    W Luan، نويسنده , , B.D Bowen، نويسنده , , C.J Lim، نويسنده , , C.M.H Brereton، نويسنده , , J.R Grace، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2000
  • Pages
    13
  • From page
    1173
  • To page
    1185
  • Abstract
    Suspension-to-membrane-wall heat transfer was studied in a pilot scale circulating fluidized bed combustor at 700 and 800°C for suspension densities of 10–70 kg/m3 with 286 μm silica sand particles. The total suspension-to-membrane-wall heat transfer coefficient is determined using the exposed-pipe-radial, insulated-pipe-tangential, fin-one-dimensional heat transfer model of Bowen et al. [B.D. Bowen, M. Fournier, J.R. Grace, Heat transfer in membrane waterwalls, Int. J. Heat Mass Transfer 34 (1991) 1043–1057]. Suspension-to-pipe and suspension-to-fin transfer is also determined from temperatures measured by embedded thermocouples. The fin accounted for about one third of the total heat transfer, and most of this portion passed through the insulated portion of the pipe.
  • Keywords
    Gas–solid suspension , Heat transfer , Fluidization , Circulating fluidized bed , Membrane wall , Radiation
  • Journal title
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER
  • Serial Year
    2000
  • Journal title
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER
  • Record number