Title of article :
Suspension-to-membrane-wall heat transfer in a circulating fluidized bed combustor
Author/Authors :
W Luan، نويسنده , , B.D Bowen، نويسنده , , C.J Lim، نويسنده , , C.M.H Brereton، نويسنده , , J.R Grace، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2000
Pages :
13
From page :
1173
To page :
1185
Abstract :
Suspension-to-membrane-wall heat transfer was studied in a pilot scale circulating fluidized bed combustor at 700 and 800°C for suspension densities of 10–70 kg/m3 with 286 μm silica sand particles. The total suspension-to-membrane-wall heat transfer coefficient is determined using the exposed-pipe-radial, insulated-pipe-tangential, fin-one-dimensional heat transfer model of Bowen et al. [B.D. Bowen, M. Fournier, J.R. Grace, Heat transfer in membrane waterwalls, Int. J. Heat Mass Transfer 34 (1991) 1043–1057]. Suspension-to-pipe and suspension-to-fin transfer is also determined from temperatures measured by embedded thermocouples. The fin accounted for about one third of the total heat transfer, and most of this portion passed through the insulated portion of the pipe.
Keywords :
Gas–solid suspension , Heat transfer , Fluidization , Circulating fluidized bed , Membrane wall , Radiation
Journal title :
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER
Serial Year :
2000
Journal title :
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER
Record number :
1070017
Link To Document :
بازگشت