Title of article
An improved data reduction method for transient liquid crystal thermography on film cooling measurements
Author/Authors
Ping-Hei Chen، نويسنده , , Pei-Pei Ding، نويسنده , , Di Ai، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2001
Pages
9
From page
1379
To page
1387
Abstract
This study proposes an improved data reduction method for the applications of transient liquid crystal thermography on film cooling effectiveness measurements. On the evaluations of film cooling effectiveness and heat transfer coefficient, an “equivalent step temperature” (EST) is proposed to replace the Duhamel’s superposition principle which is conventionally used to account for the actual temperature rises in both free-stream and injection flows rather than the ideal step temperature changes. For obtaining both values at over thousands of measured locations, the current data reduction method can effectively reduce the calculation time as compared with the conventional Duhamel’s superposition method, but adds only negligible errors.
Journal title
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER
Serial Year
2001
Journal title
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER
Record number
1070387
Link To Document