Title of article
PIV flow measurements for heat transfer characterization in two-pass square channels with smooth and 90° ribbed walls
Author/Authors
S.Y. Son، نويسنده , , K.D Kihm، نويسنده , , J.-C Han، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2002
Pages
14
From page
4809
To page
4822
Abstract
Particle image velocimetry (PIV) experiments have been carried out to study the correlation between the high-Reynolds number turbulent flow and wall heat transfer characteristics in a two-pass square channel with a smooth wall and a 90° rib-roughened wall. Detailed averaged velocity distributions and turbulent kinetic energy for both the main and the secondary flows are given for a representative Reynolds number (Re) of 30,000. The PIV measurement results were compared with the heat transfer experimental data of Ekkad and Han [International Journal of Heat Mass Transfer 40 (11) (1997) 2525–2537]. The result shows that the flow impingement is the primary factor for the two-pass square channel heat transfer enhancement rather than the flow turbulence level itself. The characteristics of the secondary flow, for example, vortexʹs shape, strength, rotating-direction and positions, are closely correlated with the wall heat transfer enhancements for both smooth and ribbed wall two-pass square channels. The rib-induced flow turbulence increases the heat transfer mainly because of the enhanced local flow impingement near the rib.
Journal title
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER
Serial Year
2002
Journal title
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER
Record number
1071309
Link To Document