Title of article
Freeze-drying of pharmaceuticals in vials on trays: effects of drying chamber wall temperature and tray side on lyophilization performance
Author/Authors
K.H. Gan، نويسنده , , R. Bruttini، نويسنده , , O.K. Crosser، نويسنده , , A.I. Liapis، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2005
Pages
13
From page
1675
To page
1687
Abstract
The effects of tray side and drying chamber wall temperature on the performance of freeze-drying of pharmaceuticals in vials arranged in clusters of hexagonal arrays on trays are studied, and the results of this work indicate that it would be beneficial to operate the lyophilization process by (i) employing freeze-dryers whose trays have no tray sides, (ii) using heat input control that runs the freeze-drying process close to the melting and scorch temperature constraints during the primary and secondary drying stages, respectively, and (iii) keeping the drying chamber wall temperature slightly higher than the melting temperature constraint during the primary drying stage, while during the secondary drying stage the drying chamber wall temperature should not be significantly lower than the scorch temperature constraint. The modeling and system formulation approach presented here provide a quantitative method that can be used in the analysis, optimization and control of the lyophilization process, as well as in the design of freeze-dryers.
Keywords
Lyophilization of pharmaceuticals in vials , Freeze drying of pharmaceuticals in vials , Tray side effect , Drying chamber wall temperature effect , Drying chamber wall temperature control
Journal title
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER
Serial Year
2005
Journal title
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER
Record number
1072040
Link To Document