• Title of article

    Calculation of dry out and post-dry out heat transfer in rod bundles using a three field model

  • Author/Authors

    Sreenivas Jayanti، نويسنده , , Michel Valette، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2005
  • Pages
    15
  • From page
    1825
  • To page
    1839
  • Abstract
    The critical heat flux (CHF) condition is an important parameter in the design and operation of nuclear reactor fuel rod assemblies. It has traditionally been evaluated using look-up tables or empirical correlations. In the present paper, a set of relations, in the form of a one-dimensional three-field model, is presented which enables a mechanistic prediction of high-quality CHF known as dry out. This also allows a more fundamental treatment of post-dry out heat transfer. The ensemble of relations is validated by comparing the predictions with data obtained from the TPTF test series of JAERI and the THTF test series of ORNL. The rod bundles have been modelled on a sub-channel basis. The effect of spacer grids on the flow and heat transfer has been studied by including their geometrical characteristics only. Good predictions of the dry out location and the post-dry out variation of the rod temperature are obtained over the range of parameters investigated in these tests, namely, in the pressure range of 30–130 bar, mass flux range of 50–800 kg/m2 s and inlet condition ranging from sub-cooled to an inlet quality of 0.89.
  • Journal title
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER
  • Serial Year
    2005
  • Journal title
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER
  • Record number

    1072053