Title of article :
High rotation number heat transfer of a 45° rib-roughened rectangular duct with two channel orientations
Author/Authors :
T.M. Liou، نويسنده , , S.W. Chang، نويسنده , , J.H. Hung، نويسنده , , S.F. Chiou، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2007
Pages :
16
From page :
4063
To page :
4078
Abstract :
An experimental study of heat transfer in a radially rotating rectangular channel of aspect ratio 1/2 with two opposite walls roughened by 45° staggered ribs is performed. Heat transfer distributions along centerlines of two rib-roughened surfaces are measured for the radially outward airflow at test conditions of Reynolds number (Re), rotation number (Ro) and density ratio (Δρ/ρ) in the ranges of 5000–15,000, 0–2 and 0.07–0.28. The rotating test rig permits the generation of heat transfer data with Ro considerably higher than previous data ranges. A selection of experimental data illustrates the individual and interactive influences of Re, Ro and buoyancy number (Bu) on local heat transfer with two channel orientations of 0° and 45°. With Ro varying from 0.1 to 2, heat transfer ratios between rotating and static channels on the stable and unstable rib-roughened surfaces with 0° (45°) of channel orientation are in the ranges of 0.5–1.42 (0.5–1.49) and 1.08–2.73 (1.06–2.21) respectively. A set of heat transfer correlations for the test geometry with channel orientations of 0° is derived to evaluate the local Nusselt number (Nu) in the periodically developed region with Re, Ro and Bu as the controlling flow parameters.
Keywords :
45° angled and staggered ribs , Channel orientation , High rotation number , Density ratio , Turbine rotor blade cooling
Journal title :
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER
Serial Year :
2007
Journal title :
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER
Record number :
1075047
Link To Document :
بازگشت