Title of article :
Effects of water and iso-propyl alcohol relative humidities on single wafer cleaning system performance
Author/Authors :
J. Koo، نويسنده , , T. Kim، نويسنده , , C. Jung، نويسنده , , J. Lee، نويسنده , , T. Kim، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2007
Pages :
11
From page :
4275
To page :
4285
Abstract :
As the pattern size scales down and the wafer size increases, the particle defects should be controlled more strictly in the modern microelectronics fabrication. Single wafer cleaning processes are introduced in the industry due to higher particle removal efficiency and lower particle reattachment possibility. In this study, the origins of watermark defects in single wafer cleaning system were identified, and the ways to avoid the problems were suggested through a model based numerical simulation. The watermark defects observed in the single wafer cleaning systems were found to originate from the failure of controlling water and iso-propyl alcohol (IPA) relative humidities in the surrounding gas. Increasing the IPA relative humidity in the surrounding gas during the drying phase could improve watermark defects and increase product yields.
Keywords :
Evaporation , Single wafer cleaning , Relative humidity , Watermark defect
Journal title :
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER
Serial Year :
2007
Journal title :
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER
Record number :
1075065
Link To Document :
بازگشت