Title of article
Heat transfer and friction factor correlation for artificially roughened duct with metal grit ribs
Author/Authors
S.V. Karmare a، نويسنده , , A.N. Tikekar b، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2007
Pages
10
From page
4342
To page
4351
Abstract
This paper presents the results of an experimental investigation of heat transfer to the airflow in the rectangular duct of an aspect ratio 10:1. The top wall surface is made rough with metal ribs of circular cross section in staggered manner to form defined grid. The roughened wall is uniformly heated and the other walls are insulated. This geometry of duct closely corresponds to that used in solar air heaters. The effect of grit geometry [i.e., relative roughness height of grid (e/Dh), relative roughness pitch of grit (p/e), relative length of grit (l/s)] on the heat transfer coefficient and friction factor is investigated. The range of variation of system parameters and operating parameters is investigated within the limits, as e/Dh: 0.035 to 0.044, p/e: 12.5–36 and l/s: 1.72–1, against variation of Reynolds number: 4000–17,000. It is observed that the plate of roughness parameters l/s = 1.72, e/Dh = 0.044, p/e = 17.5 shows optimum performance. Correlations for Nusselt number and friction factor in terms of above parameters are developed which reasonably correlate the experimental data.
Keywords
Metal grid ribs , Turbulent , Augmentation , Heat transfer , Roughness
Journal title
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER
Serial Year
2007
Journal title
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER
Record number
1075071
Link To Document