Title of article :
Effects of the location of side inflow holes on pool boiling heat transfer in a vertical annulus
Author/Authors :
Myeong-Gie Kang، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2008
Pages :
6
From page :
1707
To page :
1712
Abstract :
To investigate effects of the location of side inflow holes on pool boiling heat transfer in a vertical annulus, the location of the holes has been changed from 0.1 to 0.4 m. For the test, a heated tube of 34 mm diameter and the water at atmospheric pressure have been used. To clarify effects of the location of the inflow holes on heat transfer results of the annulus are compared to the data of a single unrestricted tube and the annulus with closed bottoms. Adoption of the side inflow holes results in higher heat transfer than that of the single unrestricted tube as the heat flux is less than 100 kW/m2. Moreover, it can remove the possibility of heat transfer deterioration at higher heat fluxes, which is a general characteristic of pool boiling in the annulus with closed bottoms. As the holes are located at 0.3 m from the bottom of the tube the most attractive results have been obtained and the enhancement in the heat transfer coefficient is 26.9% comparing to the single unrestricted tube at 160 kW/m2.
Journal title :
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER
Serial Year :
2008
Journal title :
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER
Record number :
1075326
Link To Document :
بازگشت