Title of article :
Multi-artery heat-pipe spreader: Lateral liquid supply
Author/Authors :
G.S. Hwang، نويسنده , , E. Fleming، نويسنده , , B. Carne، نويسنده , , S. Sharratt، نويسنده , , Y. Nam، نويسنده , , P. Dussinger، نويسنده , , Y.S. Ju، نويسنده , , M. Kaviany، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2011
Abstract :
We design and test a low thermal/hydraulic resistance, multi-artery heat-pipe spreader vapor chamber. Liquid (water) is supplied to a highly concentrated heat-source region through a monolayer evaporator wick and a set of lateral converging arteries, fabricated from sintered, spherical copper particles. The monolayer wick allows for a minimum evaporator resistance of 0.055 K/(W/cm2), which is related to a critical transition where the receding meniscus approaches the particle neck. Similar behavior is also observed in a monolayer-wick evaporator, partially submerged in liquid bath. After this minimum, local dryout occurs and increases the resistance. However, a continuous liquid supply through the lateral arteries does not allow for total dryout in the test limit of 580 W/cm2. These thermal/hydraulic behaviors are predicted using the local thermal equilibrium and nonequilibrium models.
Keywords :
Wick , Capillary , Vapor chamber , Converging wick , Multi-artery , Evaporator , Heat pipe , Meniscus recess , Heat spreader
Journal title :
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER
Journal title :
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER