Title of article
Analysis of single blow effectiveness in non-uniform parallel plate regenerators
Author/Authors
J.B. Jensen، نويسنده , , C.R.H. Bahl، نويسنده , , K. Engelbrecht، نويسنده , , B. Elmegaard، نويسنده , , N. Pryds، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2011
Pages
6
From page
4746
To page
4751
Abstract
Non-uniform distributions of plate spacings in parallel plate regenerators have been found to induce loss of performance. In this paper, it has been investigated how variations of three geometric parameters (the aspect ratio, the porosity, and the standard deviation of the plate spacing) affects this loss in a single blow model of a parallel-plate regenerator. Simple analytical functions for the magnitude and the time scale of the reduction of performance are presented and compared to numerical results.
Keywords
Regenerator , Modeling , Distribution , performance , Non-uniform
Journal title
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER
Serial Year
2011
Journal title
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER
Record number
1077495
Link To Document