Title of article
Real source–sink pair
Author/Authors
Sudhakar Subudhi، نويسنده , , K.R Sreenivas، نويسنده , , Jaywant H. Arakeri and J. Srinivasan، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2012
Pages
11
From page
1650
To page
1660
Abstract
This work is concerned with the interaction of a source–sink pair. The main parameters of the problem are source and sink flow rates, the axial and lateral separations of the source and sink, and the angle between the axes of source and sink. Of concern is the percentage of source fluid that enters the sink as a function of these parameters. The experiments have been carried using the source nozzle diameter of 6 mm and the sink pipe diameter of two sizes: 10 mm and 20 mm. The Reynolds numbers of the source jet is about 3200. The main diagnostics are flow visualization using dye, laser induced fluorescence (LIF), particle streak photographs and particle image velocimetry (PIV). To obtain the removal effectiveness (that is percentage of source fluid that is going through the sink pipe), titration method is used. The sink diameter and the angle between source and the sink axes do not influence efficiencies as do the sink flow rate and the lateral separation. Data from experiments have been consolidated so that these results can be used for designing sinks for removal of heat and pollutants.
Keywords
Jet , Effectiveness , LiF , PIV
Journal title
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER
Serial Year
2012
Journal title
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER
Record number
1077752
Link To Document