• Title of article

    Numerical modeling of the impact of regenerator housing on the determination of Nusselt numbers

  • Author/Authors

    K.K. Nielsen، نويسنده , , G.F. Nellis، نويسنده , , S.A. Klein، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2013
  • Pages
    9
  • From page
    552
  • To page
    560
  • Abstract
    It is suggested that the housing of regenerators may have a significant impact when experimentally determining Nusselt numbers at low Reynolds and large Prandtl numbers. In this paper, a numerical model that takes the regenerator housing into account as a domain that is thermally coupled to the regenerator fluid is developed. The model is applied to a range of cases and it is shown that at low Reynolds numbers (well below 100) and at Prandtl numbers appropriate to liquids (7 for water) the regenerator housing may influence the experimental determination of Nusselt numbers significantly. The impact of the housing on the performance during cyclic steady-state regenerator operation is quantified by comparing the regenerator effectiveness for cases where the wall is ignored and with cases where it is included. It is shown that the effectiveness may be decreased by as much as 18% for the cases considered here. A reduced number of transfer units (NTUeff) is proposed based on the calculated regenerator effectiveness that accounts for the effect of the housing heat capacity
  • Keywords
    Nusselt number , Low Reynolds number , Numerical modeling , Aqueous heat transfer fluid , Regenerator , Wall effects
  • Journal title
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER
  • Serial Year
    2013
  • Journal title
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER
  • Record number

    1079145