Title of article :
Investigation on the tribology of Zr ion implanted tool steel
Author/Authors :
N. Akbas، نويسنده , , A. Oztarhan، نويسنده , , O.R. Monteiro، نويسنده , , I.G. Brown، نويسنده ,
Issue Information :
ماهنامه با شماره پیاپی سال 2002
Pages :
6
From page :
540
To page :
545
Abstract :
AISI D3 tool steel was ion implanted with zirconium and the improvement in surface tribological properties investigated. The Zr ion implantation was done using a metal vapor vacuum arc (Mevva) broad-beam ion source, with a mean ion energy of 130 keV and at doses of 3.6×1016, 5×1016 and 1×1017 ions/cm2. Wear, friction and hardness of the implanted samples were measured and compared to the performance of unimplanted steel. The wear resistance was increased by about a factor of two, the friction remained about the same or was possibly increased by a small amount and the near-surface hardness was improved by a factor of five or more by the ion implantation. We also investigated the effect on the Zr implantation profile of the multi-component energy distribution of the ion beam.
Keywords :
Tribology , Implanted steel , Metal vapor vacuum arc
Journal title :
Wear
Serial Year :
2002
Journal title :
Wear
Record number :
1085157
Link To Document :
بازگشت